ARGO-HYTOS is a manufacturer specializing in hydraulic systems, fluid management, motion control, and filtration technology. Its product portfolio includes hydraulic filters, directional control valves, proportional valves, gear pumps, pressure switches, manifolds, power packs, and hydraulic accessories for industrial and mobile equipment applications.
Hidroman provides application-focused support for customers sourcing ARGO-HYTOS hydraulic components. Product selection should be based on the exact part number, operating pressure, flow rate, mounting dimensions, connection type, fluid requirements, and equipment specifications.
The ARGO-HYTOS product range can be organized into three main technology categories:
Fluid filtration: Suction filters, return filters, pressure filters, high-pressure filters, return-suction filters, and offline filtration units.
Fluid monitoring and control: Contamination monitoring devices, sensors, pressure switches, measurement equipment, and external filtration systems.
Fluid and motion control: Directional control valves, solenoid valves, proportional valves, pressure control valves, check valves, flow control valves, and manifolds.
The portfolio also includes SPA 01, SA4, and SMA 05 power pack series, hydraulic pumps, connection plates, reservoir solutions, and hydraulic accessories.
Hydraulic accessories support equipment installation, fluid level monitoring, maintenance, and everyday hydraulic system operation.
The following stud kits are listed for short levers associated with ISO 02, ISO 03, ISO 05, CETOP 02, CETOP 03, and CETOP 05 interfaces:
D02 — size 04
D03 — size 06
D05 — size 10
Confirm the required interface and dimensions against the manufacturer's documentation before ordering.
Listed connection sizes:
3/4-16 UNF
7/8-14 UNF
M20×1.5
M22×1.5
M27×2
G1/8
The RCA manual hand pump is listed for applications requiring manually generated hydraulic pressure. The existing Hidroman page specifies a maximum operating pressure of 250 bar (3,600 psi).
The listed description highlights a simple, reliable design, pressure and suction check valves, and a handle that can rotate through 360 degrees.
Confirm the exact connection configuration and operating limits before selecting the pump for a specific application.
SMT: Screw-in mounting accessories.
AV and TV oil drain valves: Components intended to facilitate controlled hydraulic reservoir draining and maintenance.
DG 023 and DG 902 clogging indicators: Filter condition indicators for which the existing page lists a response or switching pressure of up to 5 bar.
C5 series:
C5.3511
C5.3516
C5.3529 — thermometer-equipped version
The existing page lists a gauge length of up to 194 mm and temperature indication up to 80°C for C5.3529.
C4 series:
C4.0410
C4.0412
C4.0421
C4.0431
C4.0450
C4.0464
The C4 series includes oil level monitoring options for different reservoir and installation configurations. Verify dimensions, mounting arrangements, and connection specifications against the relevant product documentation.
Hydraulic filtration helps control particulate contamination and protect pumps, valves, actuators, and other sensitive components. Filter selection should consider flow rate, operating pressure, pressure drop, filter element specifications, oil viscosity, and the required fluid cleanliness level.
Suction filters are installed in hydraulic reservoirs or suction lines to help control contamination entering the pump circuit.
Tank-mounted models:
S0.0426
S0.0638
AS010
AS025
AS040
AS060
AS080
AS100
AS150
In-line, high-performance models:
LS025
LS035
LS 040
LS075
In-line Lightline models:
SFL 025
SFL 035
SFOL 040
SFL 075
Tank-top mounted models:
ES075
ES094
Select the appropriate configuration according to pump flow, installation requirements, and the permissible pressure drop on the suction side.
Return filters help remove particulate contamination from hydraulic fluid returning to the reservoir.
In-line, high-performance models:
D 090
D100
D170
D230
In-line Lightline models:
RFL 090
RFL 100
170
RFL 230
Tank-top or in-line, high-performance models:
FR 043
FR 072
Tank-top, high-performance models:
E 094
E103
E143
E212
E222
E303
E444
E454
E464
E 503
E644
E 703
Tank-top Lightline models:
RFT 103
RFT 143
RFT 222
RFT 454
RFT 464
Tank-mounted, high-performance models:
E441
E451
E461
E641
E700
Multifunctional filtration unit:
MFE 200
Return filter selection should account for maximum return flow, oil viscosity, cold-start conditions, filter element specifications, and allowable pressure drop.
Return-suction filters combine return and suction filtration functions in configurations intended for specific hydraulic circuit designs.
In-line, high-performance models:
E068
E088
E178
E258
Tank-top mounted, high-performance models:
E 084
E158
E198
E248
328
E498
598
E998
The codes are retained as published on the source page. The exact ordering designations for 328 and 598 should be verified with the manufacturer because the displayed entries do not include the E prefix used by several neighboring models.
FNK 0
Maximum operating pressure listed on the source page: 10 bar (145 psi).
The original text contains a corrupted nominal flow specification; confirm the exact value in the manufacturer's technical documentation.
Listed cooling capacity: up to 45 kW.
FNK 100
Maximum operating pressure listed on the source page: 10 bar (145 psi).
The source text associates the nominal flow specification with approximately 33 gpm; confirm the exact rating before specifying the unit.
Listed cooling capacity: up to 45 kW.
Filter-cooler selection should consider fluid flow, heat load, operating pressure, and the system's thermal management requirements.
Pressure filters remove contamination from hydraulic fluid under pressure.
In-line, high-performance models:
D 042
062
072
D112
D152
D 162
D232
D 332
Wordline 400 series:
HD 790
HD 990
Wordline 300 series:
HD 319
HD 419
HD 619
Wordline 200 series:
HD 152
HD 172
Wordline 100 series:
HD 049
HD 069
In-line filter series:
FNL 1000
FNL 2000
In-line high-security filter models:
HD 040
HD081
HD 150
Listed filter kit or element codes:
HD 049
HD 069
HD 172
HD319
HD419
HD619
Filter housings, replacement elements, and maintenance kits may have different ordering requirements. Confirm the exact component code and compatibility before ordering.
Bidirectional, in-line, high-performance models:
HD 417
HD 617
Flanged, high-performance models:
HD 044
HD 064
HD 314
HD 414
HD 614
High-pressure filter selection requires verification of maximum operating pressure, flow rate, connection standard, pressure differential, and filter element compatibility.
Standard breather filters:
L1.0406
L1.0506
L1.0706
L1.0807
Vandal-resistant breather filters:
L1.0808
L1.0809
LE.0716
LE.0817
LE.0827
LE.0818
LE.0819
Desiccant breathers:
LT.1021-51
LT.1325-51
Reservoir breathers help control particulate contamination entering through air exchange. Desiccant breathers can also help manage moisture in suitable applications.
Offline filtration units operate through a separate filtration circuit and can help maintain fluid cleanliness independently of the main hydraulic circuit.
Listed models:
FNA 008
FNA 016
FNA 045
FNA 040-553
FNU 008
FNS040
FNS060
FN 060
FN 300
Selection should be based on the required cleanliness level, reservoir volume, filtration cycle, flow rate, filter element, and operating conditions.
Hydraulic manifolds and connection plates allow valves and other components to be integrated into compact hydraulic assemblies. The listed products include mounting plates for CETOP directional valves, bodies for screw-in cartridge valves, and base configurations for pressure relief functions.
PD04: Series plate with side ports for ISO 4401-02 valves.
DR1-04: Series plate.
PD06: Series plate with side ports for ISO 4401-03 valves.
DR2-06: Series plate.
PD10: Series plate with side ports for ISO 4401-05 valves.
DK1-04 (06, 10): Blanking plates.
DA-06/04, 10/06: Adapter plate options.
DP-04 (06, 10): Subplate options.
DP-04 (06, 10): Subplate series.
SB-04 (06, 10): Plate or body options for screw-in valve applications.
DP6: Base manifold with pressure relief valve.
ZB06: Base section with pressure relief valve for series-plate arrangements.
ZB10: Base section with controlled pressure relief for series-plate configurations.
When selecting a manifold, verify the valve interface, port dimensions, operating pressure, flow requirements, internal circuit design, and pressure relief requirements.
Pressure switches provide electrical switching or control signals when hydraulic pressure reaches a specified threshold.
The existing Hidroman page lists the following specifications:
Sizes: 06 (D03) and 10 (D05).
Maximum pressure: 350 bar (5,100 psi).
Robust design intended to withstand vibration and shock.
Wide adjustment range, with factory presetting or field adjustment options.
Modular design and manifold integration options.
AC and DC electrical supply options.
Fluid connection: G1/4 and connection options referenced to DIN ISO 16873.
Subplate configurations referenced to ISO 4401 and DIN 24340, including CETOP 03 and CETOP 05.
Listed specifications:
Maximum pressure: 400 bar (5,800 psi).
Piezoelectric pressure sensing.
Stainless steel construction as described on the source page.
Measurement repeatability specified as ±1%.
Integrated adjustment capability.
Maximum switching frequency: 100 Hz.
Body rotatable through 320 degrees.
Listed specifications:
Maximum pressure: 400 bar (5,800 psi).
Digital pressure display.
Display and body rotation through 320 degrees.
4–20 mA analog output.
High-precision ceramic sensing element.
Robust, shock-resistant design.
Resistance to electromagnetic interference.
12-bit microprocessor-based electronics with error-code display.
Listed specifications:
Piston design for stationary and mobile applications.
Sizes: 06 (D03) and 10 (D05).
Maximum pressure: 350 bar (5,100 psi).
Precision adjustment using an Allen screw.
Factory presetting.
Silver-plated microswitches.
Modular plate and base connection.
CETOP 03 and CETOP 05 mounting options referenced to ISO 4401 and DIN 24340.
Verify the current product-specific pressure rating, electrical switching capacity, connection configuration, and certification scope before specifying a pressure switch.
ARGO-HYTOS gear pumps convert mechanical drive power into hydraulic flow for industrial and mobile hydraulic systems. The existing page lists Lightline and high-performance gear pump families.
GP0L
GP1L
GP2L
GP3L
GPL
According to the source page, the GP0L and GPL Lightline versions are intended for a single direction of rotation. Confirm the permitted rotation direction and configuration for the exact pump model.
GP1
GP2
GP3
Listed product features include:
High-quality aluminum alloy construction.
Axial clearance compensation.
Design features intended to reduce operating noise.
High volumetric efficiency.
Features intended to support extended service life.
Product options associated with SAE, ISO, DIN, and other international standards.
The existing page states volumetric efficiency of up to 98% for the high-performance series. This figure should be treated as a published series-level claim, not a guaranteed value for every configuration.
Gear pump selection should account for displacement, rotational speed, direction of rotation, operating pressure, fluid viscosity, drive interface, and duty cycle.
Directional control valves regulate the direction of hydraulic flow and control the movement of actuators such as cylinders and hydraulic motors.
RPR3-04
RPR3-06
RPR1-10
RPH2-6
RPH3-06
RPEK1-03
RPEK1-03/B
RPE2-04
RPEL1-04
RPE3-04
RPEL1-06
RPE3-06
RPER3-06
RPEA3-06
RPEW4-06
RPET3-06
RPEL1-10
RPE4-10
RPEW4-10
RPK1-06 — 4/2 directional valve.
SD2H-LA3 — screw-end configuration.
RNEH1-10
RNEH5-16
RNEH4-25
2/2 directional valves: SD2E-A2, SD2E-B2.
3/2 directional valves: PD2E1, SD2E-A3, SD2E-B3.
4/2 directional valves: SD2E-A4, SD2E-B4.
Screw-in and modular configurations:
ROE3-062S2
ROE3-062S2M
SD3E-A2
SD3E-B2
SD3E-C2
Models listed with blocking functionality:
ROE3-042S5(S6)
ROE3-042S5(S6)M
SD1E-A2
SD1E-A3 — blocking version, screw-in configuration.
SD1M-A2/L
ROR3-062
Selection should account for the required hydraulic function, 4/2 or 4/3 configuration, spool position, center condition, rated flow, pressure, actuation method, and electrical specifications.
Check valves permit flow in the intended direction while restricting reverse flow.
VJL2-304
SH1F-A3
LV1-043
LV2-043
LV1-063/S
LV1-063/M
VJO1-06/S
SC1F-A3
VJO1-04/M
SC1F-A2
MVJ3-06
VJO1-10/S
MVJ3-10
SC1F-B2
SC1F-C2
VJ3
VJS3
RJV1-05
VJR1-04/M
SC5H-Q3/I
2RJV1-06/M
SC5H-R3/I
VJR3-10/M
SCD5H-R3/I
SC5H-S3/I
SC5H-BP3/H
Listed separately on the source page:
SCC5H-Q3/I
SCC5H-S3/I
For pilot-operated check valves, verify load-holding requirements, pilot pressure, reverse-flow requirements, and application safety conditions.
Pressure control valves regulate, limit, reduce, sequence, or release pressure in hydraulic circuits.
SR1A-A2
VPP2-04/S
VPP2-04/M(R)
VPP1-06 (08, 10)
VPP2-06
VPP2-06-SV/xx-CE1017
SR1A-B2
SR1A-B2/HxSx-CE1017
VPP-R-16 (25)
VPP-R-16-xx-L-CE1017
SR4E2-B2
VPN1-06/S
VPN1-06/M(R)
SR4A-B2
VPN2-10/S
VPN2-10/MR
VPN1-20/S
VRP2-04
SP2A-A3
VRP2-06
SP2A-B3
DBV3
SS4A-A3
SU6A-U3/l
SUD6A-U4/l
SUD6A-V4/l
Select the correct pressure control valve according to pressure setting, flow, pilot requirements, cartridge or modular mounting style, and the system's safety requirements.
Flow control valves regulate hydraulic flow, adjust actuator speed, and distribute flow between circuit branches.
VSO1-04/R
ST21A-B2
VSV2
ST2(C)1A-A2
VSO1-04/M
2VS3-06
VSO3-10/M
VSK
SF22A-A2/H
SF22A-B2/H
VSS3-062/S
VSS3-062/M
SF32A-B3
SF32A-K3/l
One model entry in this section is corrupted in the source text. The original model designation should be checked against the manufacturer's documentation rather than reconstructed from incomplete text.
SFD2F-B4/l
SFD2F-D4/l
Flow control selection should consider required flow, pressure differential, fluid viscosity, temperature, and the desired degree of speed-control accuracy.
Motion control valves help regulate actuator movement and control loads in suitable hydraulic circuits.
SO5A-Q3/I
SO5A-R3/I
SO5A-T3/I
SOP5A-Q3/I
SOP5A-R3/I
SOP5A-T3/I
SOB5A-Q3/I
SOB5A-R3/I
SOB5A-S3/I
SOBD5A-R4/I
SOBD5A-S4/I
Depending on the hydraulic circuit and application, these valves can help control load movement and limit load-induced motion. Verify load pressure, pilot ratio, flow requirements, mounting style, and the manufacturer's application limits.
Proportional valves allow hydraulic flow or pressure to be controlled progressively in response to an electrical command signal.
PRM2-04
PRM7-04
PRM2-06
PRMR2-06
PRM7-06
PRM9-06
PRM6-10
PRM7-10
PRM9-10
PRM8-06
SD2P-B4
SR1P2-A2
SRN1P1-A2
SR4P2-B2
SRN4P1-B2
PP2P1-W3
PP2P3-W3
PVRM1-063
PVRM3-103
SP4P1-B4
SP4P2-B3
SPN4P1-B3
PVRR1-063
TV2-042/M
TV2-062/M
TV2-102/S
TV2-102/M
TV2-063/S
TV2-043/M
TV2-063/M
TV2-103/S
TV2-103/M
EL3E
EL4
EL6
When specifying a proportional control system, verify compatibility between the valve and electronic driver, including command signal, coil specifications, control method, flow, and pressure requirements.
The ARGO-HYTOS product portfolio includes the SPA 01, SA4, and SMA 05 power pack series.
Hydraulic power packs can be configured for the requirements of the relevant hydraulic application. Selection depends on required flow, operating pressure, duty cycle, reservoir volume, motor specifications, control options, and available installation space.
A series designation alone does not establish the exact specifications of a particular configuration. Refer to the applicable product documentation when selecting a power pack.
Looking for an ARGO-HYTOS hydraulic filter, gear pump, directional control valve, proportional valve, pressure switch, manifold, or hydraulic accessory?
Contact Hidroman with your product code and application details. To support a more accurate technical review, provide the following information where available:
Exact product or part number
Existing component label or technical datasheet
Operating pressure and flow rate
Connection and mounting dimensions
Hydraulic fluid type and operating temperature
Equipment or hydraulic system details
Required quantity
Hidroman can help review the application information, evaluate relevant product options, and discuss quotation requirements.
Send Hidroman your ARGO-HYTOS part number to request technical evaluation and a quotation for your hydraulic application.
Note: Product codes and descriptions have been compiled from the existing Hidroman ARGO-HYTOS page. Ambiguous or corrupted source specifications have been identified rather than presented as confirmed technical facts. Verify current availability, exact model configuration, certifications, and performance ratings against the manufacturer's latest documentation before ordering.