İçeriğe geç

Argo Hytos AS 100 Suction Filter

Argo Hytos AS 100 Suction Filter

Argo Hytos AS 100 Suction Filter

AS 100 Suction Filters
In-tank mounting
Connection up to G2
Nominal flow up to 200 l/min
Application
It is used in the suction line of hydraulic or lubricating circuit pumps.

Performance characteristics
Protection against failure: Thanks to full flow filtering in the suction line, especially pumps; It is protected from large dirt particles remaining in the system after manufacturing or repair or entering the system during oil filling.

Nominal flow rate up to 350 l/min / 92.5 gpm (see Selection Chart, column 2). The rated flow rates specified by ARGO-HYTOS, the following features:
Pressure drop at ν = 35 mm2 νp < 0.035 bar/s < 0.507 psi At ν = 162 SUS› Closed bypass valve at ν ≤ 200 mm2 /s / 927 SUS › flow rate connecting lines ≤ 1.5 m/s / 4.9 ft/s
Threaded connection points according to ISO 228 or DIN 13. Dimensions, see Selection Table, column 7, (other port considerations on request).

Filter fineness 100 µm
Hydraulic fluids Mineral oil and biodegradable fluids (HEES and HETG, see data sheet 00.20).
Temperature range -30 °C ... +100 °C (temporary -40 °C ... +120 °C) -22 °F ... +212 °F (temporary -40 °F ... +248 ° F)

Materials
› AS 010-00 / AS 025-01 / AS 040-01 / AS 060-01 / AS 150-01
steel end caps, support mesh steel, zinc-plated, stainless steel filter mesh (1.4301) › AS 080-01 / AS 100-01 aluminum hexagonal end cap, steel lower end cap, support mesh steel, zinc-plated, stainless steel filter mesh ( 1.4301) › AS 040-71 steel end caps, stainless steel filter mesh (1.4301) › AS 080-81 / AS 100-81 aluminum hexagonal end cap, steel bottom end cap, stainless steel filter mesh (1.4301) Viscosity at rated flow rate › ν < 60 mm2 /s / 280 SUS at operating temperature › initial viscosity equivalent to the permissible pump inlet νmax pressure (see diagram D), the function of the viscosity to be determined as basınçp (take into account the pressure loss in the connecting lines!). Mounting position Optional; preferably versions equipped with a bypass valve horizontal position. In all operating conditions (min. oil level, max. slope), suction must take place below the oil level.

In the suction line of the pumps of the hydraulic or lubricating circuits. Performance characteristics Failure protection: With full flow filtration in the suction line, especially in the pumps
protected from remaining coarse dirt particles. system after manufacture or repair, or enter the system when it is filled with oil.


Special features
Sturdy construction all-metal screen material with end caps, inner core and mesh offers:


Advantages:
› maximum reliability at increased operating temperatures
› tremendous shock and vibration resistance Construction Outer to center flow direction. The star-shaped curvature of the filter material gives the following results:
› large filter surfaces
› low pressure drop
› long service life Filter maintenance
› Cleaning in the ultrasonic bath for a few minutes. Alternatively, put a suction filter on the cleaning agent. about 15 minutes and remove the dirt outside using a brush.
› Then flush with fresh cleaning fluid from the inside to the outside. outside.
› Blow compressed air from inside to outside. outside. In any case, be careful not to get any dirt inside. (clean oil side) of the suction filter.